Service only
Events and faults 13.4 Messages and troubleshooting measures
Edition 07/2007 Technical Description DTCO 1381 13 - 37
TD00.1381.00 132 102
  VQHSBEFáGBJMFEá
&SSPSá
 00000005B3 Communication error; the software upgrade was aborted.
Possible causes
Software upgrade aborted by user.
Download interface of the DTCO 1381 defective.
Data connection interrupted or data cable defective.
Management device interface disturbed or blocked
Measures
Check download interface of the DTCO 1381.
Check data connection and data cable.
Check the interface and the function of the management
device.
Repeat software upgrade.
Note
The DTCO 1381 may not be the cause of the error.
1)
  VQHSBEFáGBJMFEá
&SSPSá''''''''
 00000005B3 The software upgrade module could not be started; the
software upgrade was aborted.
Possible causes
Internal fault of the DTCO 1381.
Measures
Check the DTCO 1381.
Repeat software upgrade.
If the error message continues to appear despite these
measures, replace the DTCO 1381.
1)
DTCO 1381 display
Picto. AP Error text MC Error code Meaning, cause and measures
1)
For these messages the memory code (MC) is not shown in the display of the DTCO 1381.