Appendix 14.4 Explanation of printout examples
Edition 07/2007 Technical Description DTCO 1381 14 - 29
TD00.1381.00 132 102
Handwritten information
fu = Location of control
f = Signature of the controller
ky = Start time
yk = End time
d = Signature of the driver
Information about the cardholder of the recorded profile
Last name of driver
First name of driver
•Card identification
Remark
Missing information about the cardholder means: no driver card inserted in card slot 1.
Beginning of the profile recording with date and time
End of the profile recording with date and time
Remark
New profiles are created:
– by inserting / withdrawing a tachograph card into / from card slot 1
– by a day change
– by a correction of the UTC time
– by a voltage interruption
Recording of speed profile
List of the defined speed ranges and period in this range
Range: 0 <= v < 1 = Vehicle motionless
The speed profile is divided into 16 zones. During installation, the individual ranges can
be adjusted individually.
Recording of rpm profile
List of the defined motor rpm ranges and period in this range
Range: 0 <= n < 1 = Motor off
Range: 3281 <= n < x = unlimited
The rpm profile is divided into 16 zones. During installation, the individual ranges can be
adjusted individually.