Data handling 4.2 The flow of data and memory behaviour
Edition 07/2007 Technical Description DTCO 1381 4 - 11
TD00.1381.00 132 102
Faults (errors) The DTCO 1381 saves faults (errors) with a resolution of one second.
The following data will be saved for every fault (error):
Calibration data The DTCO 1381 registers and saves the following calibration data in
its data memory:
• Programmed calibration parameters at the time point of the acti-
vation
• The first calibration after activation
• The first calibration in the current vehicle (depending on the
chassis number)
• The 5 most recent calibrations
• Date and purpose of the calibration
–Activation (1)
– Initial installation (2)
– Installation (3)
– Regularly inspection (4)
• Name and address of the workshop
• Number of the workshop card, issuing member state, validity
Fault Saving regulations Recorded data
Card faults • The 10 most recent driver card faults • Begin – date and time
• End – date and time
• A card’s type, number, and issuing
member state.
Recording equipment fault • The 10 most recent faults of each fault
type
• The first fault after the most recent cali-
bration
•Type of fault
•Begin – date and time
• End – date and time
• The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the fault.
If several calibrations are performed on one calendar day, only the
last calibration will be saved.