Service only
Data handling 4.2 The flow of data and memory behaviour
Edition 07/2007 Technical Description DTCO 1381 4 - 11
TD00.1381.00 132 102
Faults (errors) The DTCO 1381 saves faults (errors) with a resolution of one second.
The following data will be saved for every fault (error):
Calibration data The DTCO 1381 registers and saves the following calibration data in
its data memory:
Programmed calibration parameters at the time point of the acti-
vation
The first calibration after activation
The first calibration in the current vehicle (depending on the
chassis number)
The 5 most recent calibrations
Date and purpose of the calibration
–Activation (1)
Initial installation (2)
Installation (3)
Regularly inspection (4)
Name and address of the workshop
Number of the workshop card, issuing member state, validity
Fault Saving regulations Recorded data
Card faults The 10 most recent driver card faults Begin – date and time
End – date and time
A card’s type, number, and issuing
member state.
Recording equipment fault The 10 most recent faults of each fault
type
The first fault after the most recent cali-
bration
•Type of fault
•Begin date and time
End – date and time
The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the fault.
If several calibrations are performed on one calendar day, only the
last calibration will be saved.