EasyManua.ls Logo

Siemens VDO DTCO 1381 - Page 97

Siemens VDO DTCO 1381
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service only
Data handling 4.3 Tachograph cards
Edition 07/2007 Technical Description DTCO 1381 4 - 23
TD00.1381.00 132 102
Faults (errors) The following faults are saved on the workshop card:
Faults of the DTCO 1381
Card fault if the workshop card is the object of the fault
The following data will be saved about faults:
Fault code
Beginning – date and time (if the event continues while card
withdrawn, the date and time will be saved upon withdrawal)
End – date and time (if the event continues while card with-
drawn, the date and time will be saved upon withdrawal)
Vehicle registration number of the vehicle, in which the fault
appeared
Place of registration of the vehicle in which the fault appeared
Control activities The following data will be saved about control activities:
Date and time of the control
Number of the control card, issuing member state
•Type of control
Display, printing, or downloading of data from memory
Display, printing, or downloading of card data
Vehicle registration number of the inspected vehicle
Place of registration of the inspected vehicle
In the case of download, the time period (from / to) for which
the data was copied.
The six most recent events of all types will be saved; in total, 12
entries will be saved.
The card data download can be saved on the tachograph card only if
this happens through the DTCO 1381. In other words, the card must
be located in a card slot on the DTCO 1381.

Table of Contents