EXCITE + - Crossover: Technical Service guide- Ver. 4.1
Page 6.32
THERE IS NO
HR SIGNAL
(Hand Sendor)
Check if the +5Vdc are at the
input of the HS board.
Are present?
ARM/CPU Board
def ectiv e.
Replace it.
1
NO
YES
Check if the +5Vdc are at the
output of the ARM/CPU board.
Are present?
HS Board def ectiv e.
Replace it.
2
YES
NO
YES
Check the display
SW v ersion and the grounding
of the HS Board.
The problem persists?
3
Check and/or replace the
CU365 and CU366
cables
YES
Check the Hand Senson are
correctly connectedat to the
Connector Board.
NO
ok
Restore the connections
NO
4
Check the connection between
Hand Sensor Board and
Connector Board is ok.
YES
Restore the connections
NO
Continued on following page ...