EXCITE + - Crossover: Technical Service guide- Ver. 4.1
Pagina 8.7
8.5. ADJUSTING THE ANTI-LOCK SYSTEM
Figure 8.5-1
1. Loosen the counter-nut (a) of anti-lock
system using a 13mm wrench.
2. Adjust the distance between the magnet (b)
and the pulley magnets (c).
3. Lock down the nut again.
CAUTION: Check for both pulley
magnets, that the distance “X” is: 1≤
X ≤3mm.