EasyManua.ls Logo

Technogym EXCITE+ - Table of Configuration Parameters

Technogym EXCITE+
223 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXCITE + - Crossover: Technical Service guide- Ver. 4.1
Pagina 9.25
9.5.1. TABLE OF CONFIGURATION PARAMETERS
To correctly display the parameter values, you need to load them from the low kit,
using the “Read from low kit” function.
After any changes to the parameter values, you need to save them in the low kit using
the “Write to low kit” function
Id
(Par.)
Units Name Description
VISIO
Powered.
1
decimal
[Rt]
Transmission Ratio
145
2
[Rvel]
Speed ratio
13
3
mA
[Im]
Minimum braking
0
4
W
[Pmc]
Constant maximum power
200
5
in cents
[Km]
Power factor correction (constant torque)
100
6
0.1N
[Ca]
User friction torque
31
7
°C
[Tea]
Maximum temperature on the coil
125
8
User rpm
[RPMmin]
Minimum user SPM (start cut braking ramp)
30
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
10
User rpm
[RpmF2]
Rpm filter threshold
75
11
[Rvel] Speed ratio (decimal part)
33
12
0.1N
[D_Ca]
User delta friction torque
9
13
-
-
Enable flag for registers at address ≥ 100
-

Table of Contents