EXCITE + - Crossover: Technical Service guide- Ver. 4.1
Page 6.22
Description Meaning Solution
32
CRC fault on the
braking table.
CRC fault error on the braking
table.
This occurs when the installed
braking table has an erroneous
CRC. It is saved in the error log.
This control is not performed for
equipment which only provides for
constant RPM training sessions (e.g.
STEP/WAVE).
Re-load the braking table.
64
EEPROM Fault.
Corrupt EEPROM.
This happens when the flag relating
to the CURRENT zone and the flag
relating to the MIRROR zone (in
EEPROM) indicate results that are
not consistent.
Re-load the braking table.
128
Not used.
-
Upgrade the Firmware (FW) on the
brake board. If the same errors
occur after upgrading has been
successfully completed, the
problem is NOT the brake board.