5-35
 
5-3-7 Other Speed Control Functions 
This Section explains other functions related to Speed Control. 
 
  Speed Reached Function   
When Forward or Reverse Speed exceeds the speed set by Cn007 (Speed Reached Determined 
Value), Digital Output Contact INS operates; refer to following description: 
 
Cn007 Speed Reached Determined Value 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
Rated rotational 
speed* 1/3 
rpm  0 ~ 1.5*Rated Speed  Effective after Set  0008H 
Setting Description:  When the Forward or Reverse Speed exceeds the speed set by Cn007 (Speed 
Reached Determined Value), Digital Output Contact INS activates 
Cn007 
Speed Reached 
Determined Value
Speed
Digital Output Contact INS State
ON
OFF