EasyManua.ls Logo

TECO JSDG2S-75B-E - Tool Magazine Parameter Setting

TECO JSDG2S-75B-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-111
5-5-4 Tool Magazine Parameter Setting
Cn010/Cn056 CCW Direction Torque Command Limit Value Stage 1 / Stage 2
Initial Value Unit Setting Range Effective RS-485 Address
200 ~ 300
Note)
% 0 ~ 300 Effective after Set
Each Parameter is
different
Note) Default and setting range of parameter Cn010/Cn056/Cn011/Cn057 vary by driver model. Refer
to “7-3-1 System parameters (Cn0□□)” for details.
Cn011/Cn057 CW Direction Torque Command Limit Value Stage 1 / Stage 2
Initial Value Unit Setting Range Effective RS-485 Address
-300 ~ -200
Note)
% -300 ~ 0 Effective after Set
Each Parameter is
different
Note) Default and setting range of parameter Cn010/Cn056/Cn011/Cn057 vary by driver model. Refer
to “7-3-1 System parameters (Cn0□□)” for details.
Cn041.2 Turret mode return to zero function
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Effective after Confirmed 002CH
Setting Description:
Setting Description
0
Not Functioning
1
The driver execute turret return to zero function
after setting as 1; will automatically clear the setting
to 0 after completed.
Cn058 The Delay Time of Torque Limit Stage 1 switch to Torque Limit Stage 2
Initial Value Unit Setting Range Effective RS-485 Address
0 4ms 0 ~ 32767 Effective after Confirmed 003DH
Setting Description: After the digital output contact INP delays according to the time set by Cn058,
the torque limit switch from (Cn010, Cn011) to (Cn056, Cn057) and from
(Cn056, Cn057) to (Cn010, Cn011) after PTRG operates.
Pn306 CNC Cutter head denominator minus ratio
Initial Value Unit Setting Range Effective RS-485 Address
1 pulse 1 ~ 8388608 Effective after Confirmed 030AH/030BH
Setting Description: Set Pn306 and Pn326 to determine the reduction ratio of CNC cutter head

Table of Contents