1-22
 
1-4 Servo Driver Installation Environment Conditions and 
Methods 
1-4-1 Installation Environment Conditions 
The environment where the servo driver is installed has a direct impact on the normal function of 
the driver and its service life, therefore, the installation environment of the driver must conform to the 
following conditions:   
•  Ambient temperature: 0 ~ + 50 
℃
; ambient humidity: under 90% RH (without condensation 
conditions). 
•  Storage Temperature: - 20 ~ + 65 °C; Storage Humidity: 90% RH or less (without condensation 
conditions). 
•  Vibration: 2G or less. 
• Prevent rain dripping or humid environment. 
•  Avoid direct sunlight. 
•  Prevent oil mist and salt erosion. 
•  Prevent corrosive liquids, gas. 
•  Prevent the intrusion of powder dust, cotton wool or fine metal chips. 
•  Keep away from radioactive materials and combustibles. 
•  When installing several servos in the control panel, please leave sufficient space between each 
device to ensure enough air for heat dissipation. Meanwhile, please add heat dissipation fan to 
keep ambient temperature of servos under 50 degrees Celsius. 
•  When installing, please mount the driver in the way of vertically standing, with the front facing 
forward and the top facing up to facilitate cooling. 
•  When assembling, pay attention to avoid drilling debris and other foreign objects falling into the 
driver. 
•  When installing, make sure to fix with M5 screws. 
•  When there is a vibration source nearby (punching machine), please use a vibration absorber or 
install a vibration-proof rubber gasket if the vibration cannot be avoided. 
•  When there are large magnetic switch, fusion splicer and other noise interference sources near the 
driver that is easy to cause error operations for the driver due to external interference, at this 
time, a noise filter needs to be installed. However, the noise filter will increase the leakage of the 
current, therefore, it is necessary to install an insulation Transformer at the input end of the 
driver.