1-4 Servo Driver Installation Environment Conditions and
Methods
1-4-1 Installation Environment Conditions
The environment where the servo driver is installed has a direct impact on the normal function of
the driver and its service life, therefore, the installation environment of the driver must conform to the
following conditions:
Ambient temperature: 0 ~ + 50
; ambient humidity: under 90% RH (without condensation
conditions).
Storage Temperature: - 20 ~ + 65 °C; Storage Humidity: 90% RH or less (without condensation
conditions).
Vibration: 2G or less.
• Prevent rain dripping or humid environment.
Avoid direct sunlight.
Prevent oil mist and salt erosion.
Prevent corrosive liquids, gas.
Prevent the intrusion of powder dust, cotton wool or fine metal chips.
Keep away from radioactive materials and combustibles.
When installing several servos in the control panel, please leave sufficient space between each
device to ensure enough air for heat dissipation. Meanwhile, please add heat dissipation fan to
keep ambient temperature of servos under 50 degrees Celsius.
When installing, please mount the driver in the way of vertically standing, with the front facing
forward and the top facing up to facilitate cooling.
When assembling, pay attention to avoid drilling debris and other foreign objects falling into the
driver.
When installing, make sure to fix with M5 screws.
When there is a vibration source nearby (punching machine), please use a vibration absorber or
install a vibration-proof rubber gasket if the vibration cannot be avoided.
When there are large magnetic switch, fusion splicer and other noise interference sources near the
driver that is easy to cause error operations for the driver due to external interference, at this
time, a noise filter needs to be installed. However, the noise filter will increase the leakage of the
current, therefore, it is necessary to install an insulation Transformer at the input end of the
driver.