5-6-3 Contact Auxiliary Function 
The User can select whether the corresponding function of Digital Input Contacts SON, CCWL 
and CWL is activated. The setting is as follows: 
 
Cn002.0 Contact Auxiliary Function - Digital Input Contact SON Function 
Selection  
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  --  0 ~ 1  Power Re-set  0002H 
Setting Description:   
 
Setting  Description 
0 
Control servo activation by digital input 
contact SON.  
1 
Do not control servo activation by digital 
input contact SON; activate servo 
immediately when the power is on. 
 
  Remark: Invalid under EtherCAT & CANopen mode 
 
 
Cn002.1 Contact Auxiliary Functions--Digital Input Contact CCWL and CWL 
Function Selection 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  --  0 ~ 1  Power Re-set  0002H 
Setting Description:   
 
Setting Description 
0 
Control CCW and CW Drive Prohibit by Digital 
Input Contacts CCWL and CWL. 
1 
Do not control CCW and CW Drive Prohibit by 
Digital Input Contacts CCWL and CWL; ignore 
CCW and CW Drive Prohibit Functions.