5-132
 
5-6-5 Mechanical Brake Time Sequence 
When Servo System is vertically loaded, to prevent the load from being displaced due to gravity 
when the power is OFF, usually a Servo Motor with Mechanical Brake will be used. This Device 
provides Digital Output Contact BI to control the operation of the mechanical brake and then 
cooperate with Cn003 ( Mechanical Brake Signal Output Time) to control the Mechanical Brake Time 
Sequence. The description is as follows: 
 
Wiring Diagram 
 
 
Mechanical Brake Time Sequence 
Cn003 Mechanical Brake Signal Output Time 
Initial Value  Unit  Setting Range  Effective  RS-485 Address 
0  ms  -3000 ~ 3000  Effective after Confirm Key  0003H 
Setting Description:  The Time Sequence Diagram is as follows 
 
(Note) Before using this function, a digital output-Mechanical Brake Signal (BI) output pin must be 
planned first