EasyManua.ls Logo

TECO JSDG2S-75B-E - Mechanical Brake Time Sequence

TECO JSDG2S-75B-E
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-132
5-6-5 Mechanical Brake Time Sequence
When Servo System is vertically loaded, to prevent the load from being displaced due to gravity
when the power is OFF, usually a Servo Motor with Mechanical Brake will be used. This Device
provides Digital Output Contact BI to control the operation of the mechanical brake and then
cooperate with Cn003 ( Mechanical Brake Signal Output Time) to control the Mechanical Brake Time
Sequence. The description is as follows:
Wiring Diagram
Mechanical Brake Time Sequence
Cn003 Mechanical Brake Signal Output Time
Initial Value Unit Setting Range Effective RS-485 Address
0 ms -3000 ~ 3000 Effective after Confirm Key 0003H
Setting Description: The Time Sequence Diagram is as follows
(Note) Before using this function, a digital output-Mechanical Brake Signal (BI) output pin must be