5-89
Parameters Description Setting range Unit
Take effect
method
Related
chapter
Cn001 Control mode selection
9: CNC tool
magazine control
E: Compound tool
magazine control
-- Power reset 5-5
Cn010
First stage CCW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn011
First stage CW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn041.2
Tool tower mode reset to zero
function
0 ~ 1 --
Take effect
after setting
5-5-2
Cn056
Second stage CCW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn057
Second stage CW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn058
Delay time for the first stage torque
limit to switch to the second stage
torque limit
0 ~ 32767 4ms
Take effect
after setting
5-4-8
Tn103 Analog torque command proportioner 0 ~ 600 %/10V
Take effect
after setting
5-4-8
Tn104
Analog torque command offset
adjustmen
t
-2500 ~ 2500
mV
Take effect
after setting
5-4-8
Tn116 Analog torque command filter 0 ~ 5000 Hz
Take effect
after setting
5-4-8
Pn306
CNC tool disc denominator minus
ratio
1 ~ 8388608
-- Power reset 5-5-2
Pn307
Positioning complete determination
value
0 ~ 41943040
pulse
Take effect
after setting
5-4-9
Pn313
Internal/external position command
one-time smooth acceleration/
deceleration time constant
0 ~ 10000 ms Power reset 5-4-4
Pn314.0
Rotation direction selection (looking
from the load of the motor)
0 ~ 1
-- Power reset 5-4-5
Pn315.0 Pulse wave error amount clear mode 1 ~ 2 --
Take effect
after setting
5-4-6
Pn315.1 Origin reset offset method setting 0 ~ 1 --
Take effect
after setting
5-4-7
Pn315.2
T
urret & tool magazine reset to zero
method selection
0 ~ 1
--
Take effect
after setting
5-5-2
Pn317.0
After the origin reset has started,
origin search direction and select
origin reference point setting
0 ~ 5 --
Take effect
after setting
5-4-7
Pn317.1
After finding the origin reference
point, setting for the moving method
to search for the mechanical origin
0 ~ 2 --
Take effect
after setting
5-4-7
Pn317.2 Origin reset start mode setting 0 ~ 2 --
Take effect
after setting
5-4-7

Table of Contents