Cn090.3 No detection of linear motor encoder Z phase disconnection function
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power reset 005DH
Setting description:
Setting Description
0
Disable the do not detect pulse encoder Z phase
disconnection function
1
Enable the do not detect pulse encoder Z phase
disconnection function
Every time the driver uses the dn-11.0 pole angle for automatic detection, it will check whether the
pitch is correct and has complete positioning. If you do not want to check it every time power is
connected, you can set Cn097.3 to 1, and the linear motor pitch detection function will not be
executed.
Cn097.3 Linear motor pitch detection
Initial Value Unit Setting Range Effective RS-485 Address
0 -- 0 ~ 1 Power reset 0064H
Setting description:
Setting Description
0 Execute linear motor pitch detection function
1 Do not execute linear motor pitch detection function