6-34
Cn048 Two Stage Gain Mode Switching Delay Time 1
Initial Value Unit Setting Range Effective RS-485 Address
0 0.2ms 0
~
10000 Effective after Confirmed 0033H
Setting description: When using the two stage gain mode, the delay time from the first stage gain to
the second stage gain can be set.
Cn049
Two Stage Gain Mode Switching Time 1
Initial Value Unit Setting Range Effective RS-485 Address
0 0.2ms 0
~
10000 Effective after Confirmed 0034H
Setting description: When using two stage gain mode, the conversion time from the first stage gain to
the second stage gain can be set.
Cn050
Two Stage Gain Mode Switching Time 2
Initial Value Unit Setting Range Effective RS-485 Address
0 0.2ms 0
~
10000 Effective after Confirmed 0035H
Setting Description: When using two stage gain mode, the conversion time from the second stage
gain to the first stage gain can be set.
(1) Determine Torque Command to Switch to the Two Stage Gain Mode
When the torque command is less than the
Cn021
switching condition, use the first stage to gain
control. When the torque command is greater than the
Cn021
switching condition, then switch to the
second stage gain control. If the torque command is less than the
Cn021
switching condition again, it
will switch to the first stage gain control.
Cn021
Two Stage Gain Mode Switching Condition (Torque Command)
Initial Value Unit Setting Range Effective RS-485 Address
200 % 0
~
399 Effective after Confirmed 0017H
(2) Determine Speed Command to Switch Two Stage Gain Mode
When the speed command is less than the
Cn022
switching condition, use the first stage gain
control; when the speed command is greater than the
Cn022
switching condition, then switch to the
second stage gain control. If the speed command is less than the
Cn022
switching condition again, it
will switch to the first stage gain control.
Cn022
Two Stage Gain Mode Switching Condition (Speed Command)
Initial Value Unit Setting Range Effective RS-485 Address
0 rpm 0
~
1.5*Rated Speed Effective after Confirmed 0018H