7-126
EC912 Distance between E-Cam Sensor to cutter point
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
100 0.1mm 1 ~ 50000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
080CH -- -- O -- -- -- --
Setting Description: Measure the distance between the sensor of item to be cut and the cutter point
EC913 Acceleration/Deceleration smoothing constant of E-Cam S-curve
【
5-6-
15
】
Initial Value Unit Setting Range Effective Cn029 Reset
10 ms 0 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
080DH -- -- O -- -- -- --
Setting Description: Acceleration/Deceleration smoothing constant of E-Cam S-curve
EC914 E-Cam rotary cut synchronous time
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
10 ms 1~ 65535 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
080EH -- -- O -- -- -- --
Setting Description: Time of rotary cut synchronous zone
EC915 E-Cam rotary cut DO delay time
【
5-6-15
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 200us 0~ 10000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
080FH -- -- O -- -- -- --
Setting Description: Delay time when sending out DO signal after arriving the synchronous zone