Performance  Check  Procedure
d.  CHECK—sweep length of the  A trace Is  greater than  10 divisions.
e.  Set:
Horizontal  MODE 
B SEC/DIV 
A/B SELECT 
TRIGGER MODE 
|«- or  DELAY Control
B  INTEN
f.  CHECK—the  Delay  Time  readout
length is  greater than  10  divisions.
B
1  ms 
B Trigger 
RUNS AFTER 
Fully CCW to the lowest 
DELAY readout value 
For a visible display
Is  70.000  ms,  and  the  B  Sweep
2,  Horizontal  POSITION  Range
a.  Set:
Horizontal  MODE  A
Horizontal  POSITION  Fully CW
b.  CHECK—that  the  start  of  trace  positions  past  the  center  vertical 
graticule  line.
c.  Set  Horizontal  POSITION fully CCW.
d.  CHECK—that the  11th time marker is positioned to the left of the cen
ter vertical graticule  line.
2245A  Operators