Basic  Applications
2.  Set:
Vertical  MODE 
Horizontal  MODE
As desired. 
A
3.  Press  AUTO  SETUP button.
4.  Adjust the VOLTS/DIV control so that the  measurement  points  can be 
easily seen.
5.  Select  a  SEC/DIV  setting  that provides  the fewest number of cycles of 
the  applied waveform  necessary to  display  the  measurement  points  of 
interest.  This  is  to  improve  the  accuracy  of  cursor  placement  for  the 
measurement.
6.  Press the  TIME button to  display the time  cursors.
NOTE
The  independent cursor  ('-»|)  cannot be positioned in front 
of the  reference  cursor  f|<-  OR DELAY).
7.  Use  the |<-  OR  DELAY  control  to  position the  reference  cursor  to  the 
leftmost  point  on the waveform to  be  measured.  Use the -M  control to 
position the independent  cursor to the rightmost point to be measured. 
Then,  read the time  difference value In the top  line of crt readout.
Period  Measurem ent
This is a time-difference measurement.  Position the TIME cursors to define 
a full period  (1  cycle)  of the input waveform.  Its value is displayed.  Use the 
setup  for  making time-difference measurements  as  a guideline for making 
period measurements  (see  Figure 5-2).
5-4
2245A  Operators