VOLTAGES
AND
WAVEFORMS
The
voltages
and
waveforms
shown
on
this
diagram
were
obtained
using
the
recommended
test
equipment
and
test
set-ups
listed
below.
RECOMMENDED
TEST
EQUIPMENT
ITEM
SPECIFICATIONS
RECOMMENDED
TYPE
Oscilloscope
Frequency
response
DC
to
65
MHz
Tektronix
7603
or
7613
equipped
with
Deflection
factor
5
mV
to5
V/Div
|
7A22
Amplifier
and
7B50
Time-Base
input
impedance
10
MQ,
20
pF
unit,
or
equivalent.
Sweep
rate
500
ns
Probe
Fast
rise
10X
attenuation
probe
com-
|
Tektronix
P6053A,
or
equivalent.
patible
with
the
vertical
amplifier
of
the
test
oscilloscope.
Voltmeter
(Non-Loading
Input
impedance
10
MQ
Tektronix
7D13
Digital
Multimeter
(test
Digital
Multimeter)
Range
0-500
V
oscilloscope
must
have
readout
system}
or
Fairchild
Model
7050,
or
equivalent.
Calibration
Fixture
Used
for
loading
power
supply
for
ripple
|
Tektronix
Signal
Standardizer,
Tektronix
waveforms.
Part
Number
067-0587-01,
or
equivalent.
Voltage
Measurements
Waveforms
Voltage
measurements
on
this
diagram
were
made
under
Waveforms
shown
on
this
diagram
were
obtained
under
the
following
conditions:
the
following
conditions:
7613
OSCILLOSCOPE
UNDER
TEST.
Front
panel
controls
are
set
the
same
as
for
voltage
measurements.
A
signal
standardizer
plug-in
unit
is
installed
in
the
vertical
plug-in
position
and
a
7B53AN
Time
Base
unit
in
a
horizontal
position.
The
signal
standardizer
plug-in
unit
Turn
READOUT
to
off.
is
used
for
power
supply
loading
and
is
set
for
AUX
IN
with
a
REP
RATE
of
100
Hz.
No
signal
is
applied.
The
7B53AN
is
set
for
free
running
sweep
of
1
ms/Division.
TEST
OSCILLOSCOPE.
The
test
oscilloscope
is
AC
coupled
and
set
for
LINE
trigger.
A
7A22
Vertical
Set
knob
type
front panel
controls
(except
READ-
OUT)
to
mid-range.
Set
VERT
MODE
for
CHOP.
Set
for
NON
STORE
condition.
plug-in
unit
is
installed
and
set
as
follows:
HF
—3
dB
POINT
30
kHz
Set
TRIG
SOURCE
for
VERT
MODE.
LF
—3
dB
POINT
DC
+INPUT
AC
—INPUT
GND
No
plug-ins
are
installed.
Voltmeter
common
is
connected
to
chassis
ground.
Tolerances
of
voltages
and
waveforms
shown
are
20%.