ReelCircuitTesting−ManifoldReliefValve(SV)PressureTest
(continued)
10.Engagecuttingunits.
11.Watchpressuregaugecarefullywhileslowlyclosingtheowcontrolvalve.
12.Systempressureshouldreach207Bar(3000PSI)beforethereliefvalve
opens.
13.Setthrottletolowspeedandshutoffengine.
14.Ifspecicationismet,testpump(P1)ow(seeReelCircuitTesting−Gear
Pump(P1)FlowT est(page5–52)).Ifspecicationisnotmet,testrelief
valve(EV)solenoid,cleanorreplacevalve(seeServicingtheHydraulic
Manifold(page5–113))andretest.
15.Disconnecttesterfrommanifoldandhose.Reconnecthydraulichoseto
manifoldttingforport(M1).
Reelmaster
®
3100-D/3105-D
Page5–51
HydraulicSystem:Testing
20252SLRevA