FilteringClosed−LoopTractionCircuit
Filteringofaclosed−loophydraulicsystemafteramajorcomponentfailure(e.g.
traction(piston)pumporwheelmotor)isarequirementtopreventdebrisfrom
transmittingthroughoutthesystem.Ifaclosed−loophydraulicsystemltering
toolisnotused(toensuresystemcleanliness)repeatfailuresandsubsequent
damagetootherhydrauliccomponentsinthesystemwilloccur.T oeffectively
removecontaminationfromclosed−looptractioncircuit,useoftheT orohigh
owhydrauliclterandhydraulichosekitarerecommended(seeSpecialTools
(page2–13)).
1.Parkmachineonalevelsurface,stopengineandremovekeyfromkey
switch.
WARNING
Beforejackingupthemachine,reviewandfollowJacking
Instructions(page1–7).
2.Raiseandsupportmachinesoallwheelsareofftheground.
Note:Ifawheelmotorwasreplaced,installhighowltertotheinlet(when
travelingforward)ofnewwheelmotorinsteadoftotheinlet(whentraveling
forward)ofthetractionpump.Thiswillpreventsystemcontaminationfrom
enteringanddamagingthenewmotor.
g345088
Figure62
1.Rearwheelmotor
2.Lowertting
3.Thoroughlycleanjunctionofhydraulichoseandlowerttingonrearwheel
motor(Figure62).Disconnecthosefromlowerttingonwheelmotor.
4.ConnectT orohighowhydrauliclterinseriesbetweenwheelmotor
ttinganddisconnectedhose.Usehydraulichosekit(seeSpecialTools
(page2–13))toconnectltertomachine.Makesurethatttingandhose
connectionsareproperlytightened.
IMPORTANT
UseonlyhydraulicuidsspeciedinOperatorsManual.Other
uidscouldcausesystemdamage.
5.Afterinstallinghighowltertomachine,checkandllhydraulicreservoir
withnewhydraulicuidasrequired.