Adjustments
NeutralSwitch
g346737
Figure109
1.Neutralswitch
3.Switchbracket
2.Floorplate
Theneutralswitchisanormallyopenproximityswitchthatcloseswhenthe
tractionpedalisintheneutralposition.Theneutralswitchislocatedunderthe
oorplatenearthetractionpedal.
Adjusting
1.Beforeadjustingthetractionneutralswitch,checkandadjusttractionsystem
neutralposition(refertoTractionUnitOperatorsManual).
IMPORTANT
Topreventtractionneutralswitchdamage,makesurethatno
componentscontactswitchthroughentiretractionpedalmovement.
2.Parkthemachineonalevelsurface,engagetheparkingbrake,lowerthe
cuttingunitsandstoptheengine.Removethekeyfromthekeyswitch.
Reelmaster
®
3100-D/3105-D
Page6–5
ElectricalSystem:Adjustments
20252SLRevA