ServicingtheBedbarAdjuster
g343496
Figure176
1.Bedbarassembly5.Flangebushing9.Flatwasher
2.Compressionspring6.Capscrew10.Bedbaradjustershaft
3.Locknut7.Detent11.Washer
4.Bedbaradjusterscrew8.Locknut12.Wavewasher
RemovingtheBedbarAdjuster
1.Removethelocknut(item3inFigure176),compressionspringandwasher
frombedbaradjusterscrew(item4).
2.Removethebedbarassembly(refertoRemovingtheBedbarAssembly
(page8–10)).
3.Removethebedbaradjusterscrew(lefthandthreads)fromthebedbar
adjustershaft(item10).
4.Removelocknutandatwasherfromadjustershaft.Slideadjustershaft
andwavewasherfromcuttingunitframe.
5.Inspecttheangebushings(item5)incuttingunitframeandremoveif
necessary.
6.Ifdetentisdamaged,removeitfromcuttingunitsideplatebyremovingthe
capscrew.
InstallingtheBedbarAdjuster
1.Ifthedetent(item7Figure176)wasremoved,applyLoctite#243(or
equivalent)tothreadsofcapscrewandsecuredetenttocuttingunitside
platewithcapscrew.Tightencapscrewfrom19to21N·m(14to16ft-lb).
2.Iftheangebushings(item5)wereremoved,applyantiseizelubricantto
boreofcuttingunitframe.Alignkeyonbushingtoslotinframeandinstall
bushingsintoframe.Applyantiseizelubricanttoboreofeachangebushing.
3.Slidewavewasherontoadjustershaftandthenslideadjustershaftinto
angebushingsincuttingunitframe.Secureadjustershaftwithatwasher
Reelmaster
®
3100-D/3105-D
Page8–17
DPACuttingUnits:ServiceandRepairs
20252SLRevA