FlushHydraulicSystem(continued)
6.Reconnectallhydraulichoses,lines,andcomponentsthatweredisconnected
whiledrainingsystem.
Note:Useonlyhydraulicuidsspecied(seeTractionUnitOperator’s
Manual).Otheruidsmaycausesystemdamage.
7.Fillhydraulictankwithnewhydraulicuid.
8.Primehydraulicpumps(seePrimingHydraulicPumps(page5–64)).
9.Startengineandletitidleatlowspeedforaminimumof2minutes.Increase
enginespeedtohighspeedforaminimumof1minuteundernoload.
10.Raiseandlowercuttingunitsseveraltimes.Turnsteeringwheelfullyleft
andrightseveraltimes.
11.MovePTOswitchtoENABLEtoengagecuttingunitsandletthemrunfor
severalminutes.MovePTOswitchtoDISABLE.
12.Shutoffengineandcheckforhydraulicuidleaks.Checkuidlevelin
hydraulictankandaddcorrectamountofhydraulicuidifnecessary.
13.Operatethemachinefor2hoursundernormaloperatingconditions.
14.Checkconditionofhydraulicuid.Ifthenewuidshowsanysignsof
contamination,repeatsteps1through14againuntiluidisclean.Ifchanging
tobiodegradableuid,repeatsteps1through13againatleastonceand
untiltheuidisclean.
15.Assumenormaloperationandfollowrecommendedmaintenanceintervals.