SpindlePlug
K-LinePartNo.94-2703
Thisspindleplugcanbeusedto
preventcontaminantentryintothe
cuttingreelspindleassemblywhen
thehydraulicmotorisremoved
fromthespindle.
MeasuringContainer
K-LinePartNo.TOR4077
Usethiscontainertotest
hydraulicmotorefciency
(motorswithcasedrain
linesonly).Limittheoutlet
owfromthemotorand
measuretheleakagefrom
thecasedrainlineto
measuretheefciencyof
ahydraulicmotorwhile
thehydraulicsystem
pressurizesthemotor.
Thetablegivesthe
gallonsperminute
(gpm)conversionfor
themeasuredmilliliteror
ouncemotorcasedrain
leakage.
GPMmL/15secondsoz/15seconds
0.1953.2
0.21896.4
0.32849.6
0.437812.8
0.547316.0
0.656819.2
0.766222.4
0.875625.6
0.985228.8
1.094632.0
Reelmaster
®
3100-D/3105-D
Page2–19
SpecicationsandMaintenance:SpecialTools
20252SLRevA