4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33031
(Revision Date: Mar. 1, 2017)
4.8 UHF RFID KIT (B-EX706-RFID-U4-US/EU/AU-R)
4-43
5. Pass the ground wire through the hole in the sheet metal as shown in the photo, and secure it with
screws (PT-3x6).
6. Pull out the interface cable from the opposite side, and pass it through the opening.
7. Arrange the cables properly and secure it on the cable clamp as shown below.
Cut the old cable ties and
fasten the cables together
with the interface cable with
new cable ties.
Cable Clamp
Screw (PT-3x6)
Ground Wire
Ground Wire
Cable Guard