Technical data
OM 100.EPW 400.202002.en 19
3.1.9 Electromagnetic compatibility in line with EC directives
Immunity according to EN 61000-6-2 / EN 61131-2
Electrostatic discharge (EN 61000-4-2)
Contact
min. 8 kV
Clearance
min. 15 kV
Electromagnetic fields (EN 61000-4-3)
80 MHz 1 GHz:
10 V/m 80% AM
(1 kHz)
900 MHz ±5 MHz:
10 V/m 50% ED
(200 Hz)
Fast transients (EN 61000-4-4)
Power supply lines
2 kV
Process digital In-output
1 kV
Process analog inputs out-
puts
0.25 kV
Communication interfaces
0.25 kV
Induced high frequency (EN 61000-4-6)
0.15 80 MHz
10 V 80% AM (1 kHz)
Surge voltage 1.2/50: min. 0.5 kV (measured at AC/DC converter input)
Emission interference according to EN61000-6-4 / EN61000-4-5
RFI voltage EN 55011
150 kHz 30
MHz
(Group 1,
Class A)
RFI emissions EN 50011
30 MHz 1 GHz
(Group 1,
Class A)
Compliance with the EC Directive
Compliance with EMC directives requires correct installation in ac-
cordance with the device manual.
The person marketing the complete machine is responsible for the
electromagnetic compatibility of the overall system into which the
control system is integrated.