Technical data
38 OM 100.EPW400.202002.en
3.3.6 Wall-mounted housing: pin assignment, force transducer (channel Y)
Only hardware model EPW 400.202.1X
Note
Hardware model (2-channel) Version 22 is not provided with EPW
400.XX2.1X!
(12-pin round socket)
The force measurement on channel Y is optionally carried out using a DMS force
transducer or a measuring sensor with standardized process signal 0 - 10 V.
Standardized measuring sensor
24 V ± 5%, max. 100 mA (x = 100 mA, y = 100 mA)
Pin assignment force signal (channel Y)
12-pin round socket
put
C
B
f
G
e
j Shield o Shield
k 24 V DC o Auxiliary power for external measuring sen-
sor 24 V
a 0 V DC o Earth external
L Signal + i Input standardized measuring signal
m Signal - o Measuring signal earth
h Tare Signal tare
When measuring with internal measurement amplifier, pin E and pin L are bridged.