236
<COMMAND QSL>
Get/Set System/Site Quick Lockout
Controller Radio
QSL[\r]
QSL,[PAGE0],[PAGE1],[PAGE2],[PAGE3],[PAGE4],[PAGE5],[PAGE6],[PAGE7],[PAGE8],
[PAGE9][\r]
Radio Controller
QSL,[PAGE0],[PAGE1],[PAGE2],[PAGE3],[PAGE4],[PAGE5],[PAGE6],[PAGE7],[PAGE8],
[PAGE9][\r]
QSL,OK[\r]
[PAGE0] [PAGE9] : ########## (each # is 0 - 2)
0 : Not assigned (Displayed as - on the scanner.)
1 : On (Displayed as each number on the scanner.)
2 : Off (Displayed as * on the scanner.)
The Order of Quick Key is as same as LCD Icon.
[PAGE0] : Quick Key 1 - 9, 0
[PAGE1] : Quick Key11 - 19,10
[PAGE2] : Quick Key21 - 29,20
[PAGE3] : Quick Key31 - 39,30
[PAGE4] : Quick Key41 - 49,40
[PAGE5] : Quick Key51 - 59,50
[PAGE6] : Quick Key61 - 69,60
[PAGE7] : Quick Key71 - 79,70
[PAGE8] : Quick Key81 - 89,80
[PAGE9] : Quick Key91 - 99,90
This command is only acceptable in Programming Mode.
It cannot turn on/off the Quick Key that has no System / Site.
<COMMAND QGL>
Get/Set Group Quick Lockout
Controller Radio
QGL,[SYS_INDEX][\r]
QGL,[SYS_INDEX],##########[\r]
Radio Controller
QGL,##########[\r]
QGL,OK[\r]
########## (each # is 0 - 2) : Group Quick Key status of [SYS_INDEX].
0 : Not assigned (Displayed as - on the scanner.)
1 : On (Displayed as each number on the scanner.)
2 : Off (Displayed as * on the scanner.)
The Order of Quick Key is as same as LCD Icon (1 9, 0).
This command is only acceptable in Programming Mode.
It cannot turn on/off the Quick Key that has no Group.