ArcLight Hub User’s Guide
Screen Descriptions for NMS Client
Rev. 001 1081006 3-27
VMT network status:
0 = VMT Idle
1 = VMT Logging in
2 = VMT Logged In.
RL (Return Link) EbNo dB range as set: (This field specifies the VMT’s
current EbNo reading. The value is in 0.1 dB units and has a range on
0 to 130 (13.0 dB).
Frequency Error in Hertz:
Power Control Amplitude Error Summary in a range of dBm.:
Select RL Burst Rate: Current return link burst rate that the VMT is
transmitting with, specified in 1 Kbps increments. A value of 64 mean
64 Kbps.
Time Since Last Summary Message: Time in seconds since the last
MCDSummary message was received by the RtNMS for this VMT. -1
indicates no summary message has been received since RtNMS power
up.
Power Control State (select from list):
VMT Power control State:
0 = APC_LoggedOut
1 = APC_NormalActive
2 = APC_NormalSilent
3 = APC_AdjustRetry
4 = APC_Unresponsive
Is VMT polling? (check box and Yes/No radio buttons)
OK – Click on this button to close the screen.