EasyManua.ls Logo

Wacker Neuson WL 50 - Changing the Return Filter Element

Wacker Neuson WL 50
254 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICING AND INSPECTION
194
Changing the return lter element
The hydraulic system is equipped with a return lter Item 2
(Fig. 93). It is connected to an indicator light. An installed
bypass valve secures the return valve against positive pres-
sure.
eNVIRONmeNTAl NOTe
Let the pressure from the hydraulic uid reservoir
escape by opening the hydraulic uid ller neck
cap Item 1 (Fig. 90) before you unscrew the cover
of the lter housing Item a (Fig. 94). Otherwise,
hydraulic uid will be forced out of the lter housing
and could get into the environment.
Dispose of the old lter element and any leaking
hydraulic uid in an ecologically sound manner.
Replace the lter element of the return lter Item b.
(Fig. 94) during inspections or if the indicator light
for the return lter Item 3 (Fig. 13, page 48) on the
instrument panel is illuminated between inspection
intervals.
After installing a new lter element, the indicator
light on the instrument panel should no longer be
illuminated.
Replace the lter element in a timely manner, as
the lter‘s effect is overridden when the bypass
valve is open.

Table of Contents

Related product manuals