SERVICING AND INSPECTION
191
WL50
Fig. 91
Hydraulic fluid dip
stick
Fig. 90
Ventilation filter
1
Stop the loader on a horizontal surface and set the park-
1.
ing brake.
Lower the loader lift arms and attachment to the ground
2.
or work surface.
Stop the engine.3.
Remove the hydraulic oilller neck Item 1 (Fig. 90) slight-
4.
ly so that the pressure can escape from the reservoir
before removing the cap completely.
The dip stick is located on the underside of the air lter.
5.
Remove the dip stick (Fig. 91).
Wipe the dip stick with a clean, lint-free cleaning rag.6.
Put the dip stick back in.7.
Pull the dip stick out again.8.
Check the oil level. The oil level must be between the
9.
»minimum« and »maximum« marks.
Put the dip stick back in after checking the oil level.10.
Close the hydraulic uid ller neck item 1 (Fig. 90).11.