SERVICING AND INSPECTION
197
WL50
Servicing the axles10.7.7
The axial piston oil motor of the loader‘s drive hydraulics is
mounted on the transfer case. The transfer case is connect-
ed to the rear axle of the loader. The front axle is powered
via the drive shaft. The wheels are driven via two reduction
gears on each axle.
Service the transmission and the axles according
to the inspection intervals specied in this Opera-
tors Manual.
Checking / lling and draining screws can be found
in the same place on the front and rear axles.
Checking the axle oil level
The complete axle (transfer case, differential, axle
tube, wheel drives) shares a common oil supply.
You can check the oil level on the differential hous-
ing, the transfer case and on the wheel reduction
gears.
Fig. 95
Differential
a
b