32 Device Description WAGO I/O System 750 XTR
750-677/040-000 4PWM 24 VDC 0.2A XTR
Manual
Version 1.0.0
Table 16: Climatic and Mechanical Environmental Conditions and Shipbuilding
Ct2(2k4) (except precipitation/water/moisture)
Mechanical Environmental Conditions
15g, 11 ms, 1000 shocks per axis and
direction, half-sine
25g, 6 ms, 1000 shocks per axis and direction,
half-sine
EN 61373
Random vibration:
Category 1, classes A and B
Category 1, classes A and B
Environmental Requirements
1K5 (except precipitation and ice formation)
3K7 (except wind-driven precipitation, water
and ice formation)
C3 (except wind-driven precipitation and ice
formation)
Shipbuilding (Mechanical/Climatic Environmental Conditions and EMC)
Temperature: D (cold test with −40 °C/16 h)
Humidity: B
Vibration: B (vibration test with
acceleration amplitude 5.0g)
EMC: B
Enclosure: Required protection according
to the Rules shall be provided
upon installation on board
*)
The list of ship certifications issued is available in the section “Approvals”.