08/2012
6-52
WorkCentre 5021/5019
6.3.8
Initial Issue
General Procedures
741-034 NOHAD_FAN_FAIL_ERROR_COUNT_THRESHOLD 5 150 24 Enable Enable The threshold count for determining a Fail by the Fan Fail
Accumulated Time.
If an abnormal Fan Fail Determination Pulse Count (num-
ber of times) is detected in the Fail Accumulated Time, it
will be judged as a Fail.
(Unit: times)
741-035 NOHAD_FAN_FAIL_BYPASS 0 1 0 Enable Enable FAN Fail Bypass
0: Bypass OFF
1: Bypass ON
Table 1 NVM DRIVE & NOHAD
Chain-Link NVM Name
Setting
Range
(Minimum
Value)
Setting
Range
(Maximum
Value)
Default
Value
Write
Yes/No
Initialization
Yes/No Description