6.4.2.1.2
Initial Issue
General Procedures
6.4.2.1.2 DATA All Delete
Purpose
Erases the customer's data in the machine for security reasons when a PWB was replaced, the
machine was removed, etc.
To initialize the [Job History] that are stored in the ESS/MCU PWB.
Check the completed [Initialize Job History] at the [Job History Report].
Procedure
1. Enter the CE Diag Mode and input 999-970 in the Chain-Link.
2. Pressing the [Start] button transitions to the [Check Initialization] screen. At this time, the
[CLR] and the [Start] button will be flashing.
Figure 1 j0lj64003
3. Pressing the [Start] button starts the initialization of the [DATA All Delete].
• An animation will be displayed to indicate that it is in progress.
Figure 2 j0lj64004
4. When the initialization has completed successfully, [End] will flash twice -> remain ON to
indicate the completion of the [DATA All Delete] initialization.
5. Pressing the [Clear All] button returns you to the [Chain-Link Number Entry] screen.