3.6 Device-specific Settings
3.6.2 Detailed Module Settings
3-27
3
Machine Controller Setup
Link Assignment Tab Page
The Link Assignment Tab Page displays the assignment settings for all slave devices that were
detected during self-configuration (MECHATROLINK-connected devices, such as SERVO-
PACKs or distributed I/O).
Displayed Items
The following table lists the items that are displayed on the Link Assignment Tab Page.
For the valid setting ranges and setting precautions, refer to the descriptions of the items on
the following pages.
Item Details
This section provides details on the items that are displayed on the Link Assignment Parame-
ters Tab Page.
No. Item Description
ST # Displays the station number.
ADR Sets the station address of the slave station.
ExADR
Sets the individual extended addresses when multi-station modules
(multi-slaves) are grouped together as a single node.
VENDOR Sets the vendor name of the device.
DEVICE Sets the slave model.
PROFILE Sets the profile to use.
BYTE Sets the number of transmission bytes.
INPUT Sets the first register address of the input area.
OUTPUT Sets the first register address of the output area.
D Enables or disables the I/O registers.
SIZE Sets the input or output size in words.
SCAN Sets the scan in which the input or output is performed.
Comment Used to enter a comment of up to 32 characters.
Always save all settings to the flash memory after changing them.