14.1 List of Parameters
14.1.2 List of Parameters
14
Parameter Lists
14-31
Pn516
2
Input Signal Selections
7
0000 to
FFFF
8888 All
After
restart
Setup
Pn517
2
Output Signal Selec-
tions 5
0000 to
0666
0654 All
After
restart
Setup
page
6-7
Pn518
*2
Safety Module-Related
Parameters
––All
Pn51B 4
Motor-Load Position
Deviation Overflow
Detection Level
0 to
1,073,741,824
1 refer-
ence
unit
1000 Rotary
Immedi-
ately
Setup
page
10-8
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
FSTP (Forced Stop Input) Signal Allocation Reference
0 Enable drive when CN1-40 input signal is ON (closed).
page 6-105
1 Enable drive when CN1-41 input signal is ON (closed).
2 Enable drive when CN1-42 input signal is ON (closed).
3 Enable drive when CN1-43 input signal is ON (closed).
4 Enable drive when CN1-44 input signal is ON (closed).
5 Enable drive when CN1-45 input signal is ON (closed).
6 Enable drive when CN1-46 input signal is ON (closed).
7
Set the signal to always prohibit drive (always force the motor to
stop).
8
Set the signal to always enable drive (always disable forcing the
motor to stop).
9 Enable drive when CN1-40 input signal is OFF (open).
A Enable drive when CN1-41 input signal is OFF (open).
B Enable drive when CN1-42 input signal is OFF (open).
C Enable drive when CN1-43 input signal is OFF (open).
D Enable drive when CN1-44 input signal is OFF (open).
E Enable drive when CN1-45 input signal is OFF (open).
F Enable drive when CN1-46 input signal is OFF (open).
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X
ALO1 (Alarm Code Output) Signal Allocation
0 Disabled (the above signal output is not used).
1 Output the signal from the CN1-25 or CN1-26 output terminal.
2 Output the signal from the CN1-27 or CN1-28 output terminal.
3 Output the signal from the CN1-29 or CN1-30 output terminal.
4 Output the signal from the CN1-37 output terminal.
5 Output the signal from the CN1-38 output terminal.
6 Output the signal from the CN1-39 output terminal.
n.X
ALO2 (Alarm Code Output) Signal Allocation
0 to 6
The allocations are the same as the ALO1 (Alarm Code Output) signal alloca-
tions.
n.X
ALO3 (Alarm Code Output) Signal Allocation
0 to 6
The allocations are the same as the ALO1 (Alarm Code Output) signal alloca-
tions.
n.X Reserved parameter (Do not change.)