14.1 List of Parameters
14.1.2 List of Parameters
14-32
Pn51E 2
Position Deviation Over-
flow Warning Level
10 to 100 1% 100 All
Immedi-
ately
Setup
page
12-46
Pn520 4
Position Deviation Over-
flow Alarm Level
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
page
8-8,
page
12-5
Pn522 4
Positioning Completed
Width
0 to
1,073,741,824
1 refer-
ence
unit
7All
Immedi-
ately
Setup
page
6-36
Pn524 4 Near Signal Width
1 to
1,073,741,824
1 refer-
ence
unit
107374
1824
All
Immedi-
ately
Setup
page
6-37
Pn526 4
Position Deviation Over-
flow Alarm Level at
Servo ON
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
page
8-8
Pn528 2
Position Deviation Over-
flow Warning Level at
Servo ON
10 to 100 1% 100 All
Immedi-
ately
Setup
page
8-8
Pn529 2
Speed Limit Level at
Servo ON
0 to 10,000
1 min
-1
10000 Rotary
Immedi-
ately
Setup
page
8-8
Pn52A 2
Multiplier per Fully-
closed Rotation
0 to 100 1% 20 Rotary
Immedi-
ately
Tuning
page
10-8
Pn52B 2 Overload Warning Level 1 to 100 1% 20 All
Immedi-
ately
Setup
page
5-45
Pn52C 2
Base Current Derating
at Motor Overload
Detection
10 to 100 1% 100 All
After
restart
Setup
page
5-45
Pn52F 2
Monitor Display at
Startup
0000 to
0FFF
0FFF All
Immedi-
ately
Setup
page
13-3
Pn530
2
Program Jogging-
Related Selections
0000 to
0005
0000 All
Immedi-
ately
Setup
page
7-20
Pn531 4
Program Jogging Travel
Distance
1 to
1,073,741,824
1 refer-
ence
unit
32768 All
Immedi-
ately
Setup
page
7-20
Pn533 2
Program Jogging Move-
ment Speed
1 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
500 Rotary
Immedi-
ately
Setup
page
7-20
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Program Jogging Operation Pattern
0
(Waiting time in Pn535 Forward by travel distance in Pn531) × Number of
movements in Pn536
1
(Waiting time in Pn535 Reverse by travel distance in Pn531) × Number of
movements in Pn536
2
(Waiting time in Pn535 Forward by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 Reverse by travel distance in Pn531) × Number of
movements in Pn536
3
(Waiting time in Pn535 Reverse by travel distance in Pn531) × Number of
movements in Pn536
(Waiting time in Pn535 Forward by travel distance in Pn531) × Number of
movements in Pn536
4
(Waiting time in Pn535 Forward by travel distance in Pn531 Waiting time
in Pn535 Reverse by travel distance in Pn531) × Number of movements in
Pn536
5
(Waiting time in Pn535 Reverse by travel distance in Pn531 Waiting time
in Pn535 Forward by travel distance in Pn531) × Number of movements in
Pn536
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)
n.X Reserved parameter (Do not change.)

Table of Contents

Related product manuals