5.6 F: Option Settings
158 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
■ F6-07: NetRef/ComRef Function Preselection Capability
Selects how multi-step speed inputs are treated when the NetRef command is set.
Setting 0: Multi-step speed operation disabled
If the NetRef command is selected, multi-step speed input frequency references are disabled (like Yaskawa F7 drives).
Setting 1: Multi-step speed operation enabled
Even if the NetRef command is selected, multi-step speed inputs are still active and can override the frequency reference
from the communications option (like Yaskawa V7 drives).
■
F6-08: Reset Communication Parameters
Determines whether communication-related parameters (F6-) are reset when the drive is initialized using parameter
A1-03.
Setting 0: Do not reset parameters F6- when the drive is initialized with A1-03
Setting 1: Reset F6- when the drive is initialized with A1-03
Note: F6-08 is not reset when the drive is initialized, but does determine whether initializing the drive with A1-03 resets the other
communication parameters F6-.
■ F6-64 to F6-71: Dynamic Assembly Parameters (Reserved)
◆ CC-Link Parameters
Parameters F6-04, F6-10, F6-11, and F6-14 set up the drive to operate on a CC-Link network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card CC-Link Installation Manual and
Technical Manual.
◆ PROFIBUS-DP Parameters
Parameters F6-30 through F6-32 set up the drive to operate on a PROFIBUS-DP network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card PROFIBUS-DP Installation Manual
and Technical Manual.
◆ CANopen Parameters
Parameters F6-35 and F6-36 set up the drive to operate on a CANopen network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card CANopen Installation Manual and
Technical Manual.
◆ DeviceNet Parameters
Parameters F6-50 through F6-63 set up the drive to operate on a DeviceNet network.
For details on parameter settings, refer to the YASKAWA AC Drive-Option Card DeviceNet Installation Manual and
Technical Manual.
No. Parameter Name Setting Range Default
F6-07 NetRef/ComRef Function Preselection Capability 0, 1 0
No. Parameter Name Setting Range Default
F6-08 Reset Communication Parameters 0, 1 0
No. Parameter Name Setting Range Default
F6-64 to F6-71 Dynamic Assembly Parameters (Reserved) 0 to FFFFH 0