2.2 Mechanical Installation
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual 33
Mechanical
Installation
2
2.2 Mechanical Installation
This section outlines specifications, procedures, and environment for proper mechanical installation of the drive.
Installation Environment (Heatsink-Cooled Drive, Finless Drive)
To help prolong the optimum performance life of the drive, install the drive in the proper environment. The table below
provides a description of the appropriate environment for the drive.
Table 2.1 Installation Environment
NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project
construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during
installation. Remove the temporary cover before startup, as the cover will reduce ventilation and cause the drive to overheat.
NOTICE: Avoid placing drive peripheral devices, transformers, or other electronics near the drive as the noise created can lead to
erroneous operation. If such devices must be used in close proximity to the drive, take proper steps to shield the drive from noise.
Environment Conditions
Installation Area Indoors
Ambient Temperature
-10 °C to +50 °C (Heatsink-Cooled Drive)
-10 °C to +50 °C (Finless Drive)
If using the finless drive in temperatures greater than 35 °C, either takes steps to ensure proper airflow around the
unit or derate drive capacity. Refer to Temperature Derating on page 314 for details.
Drive reliability improves in environments without wide temperature fluctuations.
When using an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air temperature
inside the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
Humidity 95% RH or less and free of condensation
Storage Temperature -20 °C to +60 °C
Surrounding Area
Install the drive in an area free from:
oil mist and dust
metal shavings, oil, water or other foreign materials
radioactive materials
combustible materials (e.g., wood)
harmful gases and liquids
excessive vibration
chlorides
direct sunlight
Altitude 1000 m or lower
Vibration
10 to 20 Hz at 9.8 m/s
2
20 to 55 Hz at 5.9 m/s
2
Orientation Install the drive vertically to maintain maximum cooling effects.