No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
OL
V
P
M
b1-03 Stopping Method Selection
Selects the stopping method when the run command is
removed.
0: Ramp to Stop
1: Coast to Stop
2: DC Injection Braking to Stop
3: Coast with Timer
(A new run command is ignored if received before the
timer expires)
0 to 3 0 S S S 182 107
DC Injection Braking at Stop cannot be
selected when using Open Loop Vector for
PM motors.
Contains a brief description
of each parameter and
the settings available.
Lists the initial setting when the
drive is first shipped from the
factory. Note that this setting
can vary based on the control
mode selected for the drive.
Access
Level
S
O
Set Up Mode
Write Read Only Write Read Only
Parameter
Setting Mode
Lists the register address used
when running MEMOBUS
communications.
Indicates the control modes where each parameter
is available, and whether the setting value for that
parameter can be edited (write) or only viewed
(read).