4.4 Start-up Flowcharts
86 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Subchart A3: Operation with Permanent Magnet Motors
Figure 4.9, Flowchart A3, describes tuning for PM motors in Open Loop Vector Control. PM motors can be used for
energy savings in reduced or variable torque applications.
Figure 4. 9
Figure 4.9 Operation with Permanent Magnet Motors
YES
NO
From
Flowchart
A
Set the motor code to
parameter E5-01
Return to
Flowchart
A
Motor code is known ?
For parameter E5-01
(for Yaskawa PM Motors)
Enter “FFFF” to parameter
E5-01
Enter the motor data into
parameters E5-02 to E5-24