A.6 Drive Derating Data
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual 315
Specifications
A
Figure A.2
Figure A.2 Ambient Temperature and Installation Method Derating
Altitude Derating
The drive standard ratings are valid for an installation altitude up to 1000 m. If the altitude exceeds 1000 m both the drive
input voltage and the rated output current must be derated for 1% per 100 m. The maximum altitude is 3000 m.
40
50
0
30 35
50
70
80
85
100
Drive
Rating
(%)
Ambient tem
p (
°
C)
L8-12
L8-35 = 0 (Heatsink-Cooled Drive
L8-35 = 2
(NEMA Type 1 Drive)
L8-35 = 1
(Side-by-side Mounting)
L8-35 = 3
(Finless Drive or External
Heatsink Installation)

Table of Contents

Related product manuals