5.9 n: Special Adjustments
212 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
■ n8-91: Output Voltage Limit ld Limit
Sets the limit value for the ld operation of the feedback type output voltage limitation. This setting is available only at n8-
87 = 0.
Note: This parameter is valid from software version 6002 or later.
◆ n9: Hardware Settings
Using these parameters, the drive output voltage can be adjusted.
■
n9-10: AVR Time Constant
Sets the delay time constant that is used to adjust the output voltage when the DC bus voltage changes.
■
n9-12: On-Delay Compensation Time
Sets the time value used for IGBT On-delay compensation.
■
n9-62: On-Delay Compensation Derating Start Frequency
Sets the frequency at which the drive begins to compensate the output voltage for the IGBT On-Delay.
■
n9-63: On-Delay Compensation Disable Frequency
When operating a high-speed motor at low speeds, n9-62 sets the frequency at which the drive stops compensating the
switching delay in the DC bus.
No. Name Setting Range Default
n8-91 Output Voltage Limit ld Limit 0 to -200% -50%
No. Name Setting Range Default
n9-10 AVR Time Constant 0.0 to 100.0 ms 1.0 ms
No. Name Setting Range Default
n9-12 On-Delay Compensation Time 0.00 to 20.00 ms
Determined by
o2-04
No. Name Setting Range Default
n9-62 On-Delay Compensation Derating Start Frequency 0.0 to [E1-04] Hz 0.0 Hz
No. Name Setting Range Default
n9-63 On-Delay Compensation Disable Frequency 0.0 to [E1-04] Hz 0.0 Hz