8.3 Connecting Peripheral Devices
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual 299
Peripheral Devices &
Options
8
8.3 Connecting Peripheral Devices
Figure 8.1 illustrates how the drive and motor connect together with various peripheral devices.
• Refer to peripheral device option manual for detailed installation instructions.
Figure 8.1
Figure 8.1 Connecting Peripheral Devices
Note: Note that if the drive is set to trigger a fault output whenever the fault restart function is activated (L5-02 = 1), then a sequence to
interrupt power when a fault occurs will result in shutting off the power to the drive as the drive attempts to restart itself. The
default setting for L5-02 is 0 (fault output active during restart attempt).
<1> Never connect the comm. port on the drive to the LAN port on a PC. This can damage the drive and the PC.
Drive
Ground
U/T1 V/T2 W/T3R/L1 S/L2
1+2+
T/L3
B1 B2
Surge
absorber
C reactor
Input side
noise filter
DC reactor
Braking resistor unit
or breaking resistor
Output side
noise filter
Power
Supply
Line
breaker
(MCCB)
Leakage
breaker
Engineering software tools
PC
DriveWizard
Ground
Motor
<1>