EasyManua.ls Logo

YASKAWA T1000V - A.4 DRIVE SPECIFICATIONS

YASKAWA T1000V
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A.4 Drive Specifications
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual 311
Specifications
A
A.4 Drive Specifications
Note: Perform rotational Auto-Tuning to obtain OLV performance specifications.
Note: For optimum performance life of the drive, install the drive in an environment that meets the environmental conditions.
Item Specification
Control
Characteristics
Control Method
The following control methods are available:
Open Loop Vector Control (current vector), V/f Control, and PM Open Loop Vector for
(for use with SPM and IPM)
Frequency Control Range 0.01 to 400 Hz
Frequency Accuracy
Digital input: within ±0.01% of the max output frequency (-10 to +50 °C)
Analog input: within ±0.5% of the max output frequency (25 °C ±10 °C)
Frequency Setting Resolution
Digital inputs: 0.01 Hz
Analog inputs: 1/1000 of maximum output frequency
Output Frequency Calculation
Resolution
1/2
20
x Maximum output frequency (E1–04)
Frequency Setting Signal
Main frequency reference: 0 to +10 Vdc (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA
(250 Ω)
Main speed reference: Pulse Train Input (max 32 kHz)
Starting Torque
200%/0.5 Hz (Open Loop Vector Control, HD rating, IM of 4.0 kW or smaller), 50%/6
Hz (PM Open Loop Vector Control)
Speed Control Range
1:100 (Open Loop Vector Control), 1:40 (V/f Control), 1:10 (PM Open Loop Vector
Control)
Speed Control Accuracy ±0.2% in Open Loop Vector Control <1>
Speed Response
5 Hz (25 °C ±10 °C) in Open Loop Vector Control
(excludes temperature fluctuation when performing Rotational Auto-Tuning)
Torque Limit Open Loop Vector Control only. Adjustable in 4 quadrants.
Accel/Decel Time 0.00 to 6000.0 s (allows four separate settings for accel and decel)
Braking Torque
Instantaneous Average Decel Torque
<2>: 0.1/0.2 kW: over 150%, 0.4/0.75 kW: over
100%, 1.5 kW: over 50%, 2.2 kW and above: over 20%
Continuous Regen Torque: 20%,
125% with a Braking Resistor Unit
<3>: (10% ED) 10 s with an internal braking resistor.
V/f Characteristics User-set program available.
Functions
Momentary Power Loss Ride-Thru
Speed Search
Over/Undertorque Detection
Torque Limit, Multi-Step Speed (9 steps max)
Accel/Decel Time Switch
S-Curve Accel/Decel
3-Wire Sequence
Rotational Auto-Tuning
Stationary Auto-Tuning of Line-to-Line Resistance
Dwell
Cooling Fan ON/OFF
Slip Compensation
Torque Compensation
Frequency Reference Upper/Lower Limit
DC Injection Braking (start and stop)
PID Control (with Sleep Function)
Energy Saving
MEMOBUS/Modbus (RS-485/422 Max 115.2 kbps)
Fault Reset
Parameter Copy
Disturb Function

Table of Contents