1.2 Model Number and Nameplate Check
24 YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
■ Single-Phase 200 V
■ Three-Phase 200 V
■ Three-Phase 400 V
Normal Duty Heavy Duty
No.
Max Motor
Capacity kW
Rated Output
Current A
No.
Max Motor
Capacity kW
Rated Output
Current A
0001 0.2 1.2 0001 0.1 0.8
0002 0.4 1.9 0002 0.2 1.6
0003 0.75 3.3 0003 0.4 3
0006 1.1 6 0006 0.75 5
0010 2.2 9.6 0010 1.5 8
0012 3.0 12 0012 2.2 11
Normal Duty Heavy Duty
No.
Max Motor
Capacity kW
Rated Output
Current A
No.
Max Motor
Capacity kW
Rated Output
Current A
0001 0.2 1.2 0001 0.1 0.8
0002 0.4 1.9 0002 0.2 1.6
0004 0.75 3.5 0004 0.4 3
0006 1.1 6 0006 0.75 5
0010 2.2 9.6 0010 1.5 8
0012 3.0 12 0012 2.2 11
0020 5.5 19.6 0020 4.0 17.5
0030 7.5 30 0030 5.5 25
0040 11 40 0040 7.5 33
0056 15 56 0056 11 47
0069 18.5 69 0069 15 60
Normal Duty
<1> IP00 is available for CIMR-TC2V0069 only.
<2> Drives with these specifications do not guarantee complete protection for the specified environmental condition.
Heavy Duty
No.
Max Motor
Capacity kW
Rated Output
Current A
No.
Max Motor
Capacity kW
Rated Output
Current A
0001 0.4 1.2 0001 0.2 1.2
0002 0.75 2.1 0002 0.4 1.8
0004 1.5 4.1 0004 0.75 3.4
0005 2.2 5.4 0005 1.5 4.8
0007 3.0 6.9 0007 2.2 5.5
0009 4.0 8.8 0009 3.0 7.2
0011 5.5 11.1 0011 4.0 9.2
0018 7.5 17.5 0018 5.5 14.8
0023 11 23 0023 7.5 18
0031 15 31 0031 11 24
0038 18.5 38 0038 15 31
<1>
CIMR- T C 2 V 0001 B M A
Drive
No.
Region
code
C
Europe
No. Voltage Class
2 3-phase, 200-240 Vac
B 1-phase, 200-240 Vac
4 3-phase, 380-480 Vac
No. No.Enclosure
BIP20
AIP00
J Finless
(IP20)
L Finless
(IP00)
Environmental
Specification
<2>
M
Humidity-and
dust-resistant
T1000 Series Design Revision
Order