EasyManua.ls Logo

3Com Switch 4800G 24-Port - Configuring the Collaboration Function; Configuring Trap Delivery

3Com Switch 4800G 24-Port
1246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Collaboration Function 1061
Configuring the
Collaboration
Function
Collaboration is implemented by establishing collaboration entries to monitor the
detection results of the current test group. If the number of consecutive probe
failures reaches the threshold, the configured action is triggered.
Follow these steps to configure the collaboration function:
c
CAUTION: You cannot modify the content of a reaction entry using the reaction
command after the collaboration object is created.
Configuring Trap
Delivery
Traps can be sent to the network management server when test is completed, test
fails or probe fails.
Configuration prerequisites
Before configuring trap delivery, you need to configure the destination address of
the trap message with the snmp-agent target-host command, create an NQA
test group, and configure related parameters. For the introduction to the
snmp-agent target-host command, refer to “SNMP Configuration” on page
931.
Configure the source IP
address of a probe request in
a test operation
source ip ip-address Optional
By default, no source IP
address is specified.
The source IP address must be
that of an interface on the
device and the interface must
be up. Otherwise, the test will
fail.
Configure common optional
parameters
Refer to “Configuring
Optional Parameters Common
to an NQA Test Group” on
page 1062
Optional
To do… Use the command… Remarks
To do… Use the command… Remarks
Enter system view system-view -
Enter NQA test group view nqa entry admin-name
operation-tag
-
Enter test type view of the test
group
type { dhcp | dlsw | ftp |
http | icmp-echo | snmp |
tcp | udp-echo }
The collaboration function is
not supported in UDP-jitter
tests.
Create a Reaction entry reaction item-num
checked-element probe-fail
threshold-type consecutive
occurrences [ action-type
{ none | trigger-only }]
Required
Not created by default.
Exit to system view quit -
Create a Track object and
associate it with the specified
Reaction entry of the NQA
test group
track entry-number nqa
entry admin-name
operation-tag reaction
item-num
Required
Not created by default.

Table of Contents